Get in touch 07891 410 960
Fault finder

Boiler Overheating and Locking Out

The boiler runs hot for a minute or two, then shuts down on a fault before the room reaches temperature..

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes

The boiler runs hot for a minute or two, then shuts down on a fault before the room reaches temperature.

What is actually going on

The boiler runs hot for a minute or two, then shuts down on a fault before the room reaches temperature.

The realistic causes, in order

Poor circulation from a blocked heat exchanger, a sludged system or a partially closed valve, so heat can't leave the boiler A pump running too slowly, or set to a head that no longer suits the system after radiators were added A failed overheat thermostat or flow sensor reading high when the water isn't actually that hot

What we test on site

Flow and return temperature differential across the boiler under load — a wide split points at circulation Pump performance and speed setting against the system's actual resistance System water quality, magnetite content and filter condition

Questions we get asked

What causes an overheat lockout on a gas boiler?

Poor circulation from a blocked heat exchanger, a sludged system or a partially closed valve, so heat can't leave the boiler

What normally puts an overheat lockout right?

Fixing circulation usually means a filter, a flush or a valve correction — cheaper than the boiler damage that follows if it's ignored.

Is it safe to keep using the system with an overheat lockout?

Repeated overheat lockouts should not be reset again and again. The lockout is doing its job; the underlying circulation fault is what needs fixing.