Boiler Short Cycling On and Off

The burner lights, runs for a minute or two, drops out and relights, over and over..

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes

The burner lights, runs for a minute or two, drops out and relights, over and over.

What is actually going on

The burner lights, runs for a minute or two, drops out and relights, over and over.

The realistic causes, in order

An oversized boiler on a small load — the system can't absorb the minimum output, especially in mild weather Restricted circulation from sludge, a blocked filter or a stuck thermostatic valve Controls fighting each other, such as a boiler thermostat set low against a room stat set high

What we test on site

Burner run time and cycle count over a real heating period, not a two-minute test Flow and return differential to see how quickly heat is being carried away Control strategy, including whether weather compensation or load compensation is available and unused

Get a boiler that short cycles diagnosed properly

Correcting flow temperature, control strategy and circulation usually settles it without replacing anything.

Questions we get asked

What causes a boiler that short cycles on a gas boiler?

An oversized boiler on a small load — the system can't absorb the minimum output, especially in mild weather

What normally puts a boiler that short cycles right?

Correcting flow temperature, control strategy and circulation usually settles it without replacing anything.

Is it safe to keep using the system with a boiler that short cycles?

Short cycling wastes gas and wears ignition components. It is a system and controls problem more often than a broken part.

Where to go next