Boiler Pressure Too High

The gauge sits well above 2.5 bar when hot, and water occasionally discharges from a pipe outside..

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes

The gauge sits well above 2.5 bar when hot, and water occasionally discharges from a pipe outside.

What is actually going on

The gauge sits well above 2.5 bar when hot, and water occasionally discharges from a pipe outside.

The realistic causes, in order

A filling loop left open, or a filling valve passing slightly, continuously adding mains water A waterlogged expansion vessel with no air cushion left to absorb expansion A failing plate heat exchanger letting mains pressure cross into the sealed heating circuit

What we test on site

Cold and hot pressure readings taken twenty minutes apart to see how far the system swings Vessel pre-charge with the system depressurised, re-charged to the manufacturer's figure if the diaphragm is intact The filling loop for passing, by isolating it and re-testing

Questions we get asked

What causes boiler pressure that climbs too high on a gas boiler?

A filling loop left open, or a filling valve passing slightly, continuously adding mains water

What normally puts boiler pressure that climbs too high right?

Recharging or replacing the expansion vessel resolves most cases and stops the relief valve wearing out.

Is it safe to keep using the system with boiler pressure that climbs too high?

Do not repeatedly bleed radiators to control high pressure. That removes system inhibitor and hides the real fault.