Get in touch 07891 410 960
Hot water

Converting a vented cylinder to unvented

You can't just connect an unvented cylinder to a vented system. You can replace the system — and whether that is worthwhile depends mostly on your mains supply.

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes
Tall white unvented hot water cylinder with safety valves in an airing cupboard

A vented cylinder is fed by a cold water tank in the loft and relies on gravity for pressure, which is why showers in older homes can feel weak upstairs. An unvented cylinder is fed straight from the mains and stores hot water at mains pressure, so taps and showers throughout the house run harder.

The question people ask is whether they can simply swap one for the other. The honest answer is that it is a conversion, not a swap. The loft tanks usually come out, the cylinder changes, safety equipment goes in, and the mains supply has to be able to cope.

What has to be true before it makes sense

These are the checks that decide whether a conversion is worth doing.

  • Mains pressure and flow rate good enough to supply several outlets at once — flow matters as much as pressure
  • A suitable route for the safety discharge pipe to terminate safely and visibly
  • Room for the cylinder and its expansion vessel, which may differ in size from the old tank
  • Pipework to the bathrooms that will take mains pressure; very old joints may need attention
  • An installer qualified for unvented hot water work, because the safety devices are there for good reason

What changes, side by side

Vented (loft tank)Unvented (mains fed)
Pressure at tapsDepends on tank heightClose to mains pressure
Loft tanksNeededUsually removed
Safety devicesOpen vent pipeTemperature and pressure relief valves, expansion vessel
Annual checkGood practiceRecommended for the safety components
If mains is weakUnaffectedPerformance drops

Why flow rate is the deciding factor

Pressure is how hard water pushes; flow is how much arrives. A house can show decent pressure on a gauge yet only deliver a modest flow once two taps are open. An unvented cylinder can only give out what the mains gives it, so a weak flow means disappointing showers whatever the cylinder costs.

That is why a flow test at the kitchen tap is the first thing a sensible installer does. Our guide to water pressure versus flow rate explains the difference in more detail.

What the survey looks at

A proper survey before a conversion covers more than the cylinder cupboard. The installer will test mains pressure and flow at the incoming supply, look at the size and age of the supply pipe, check where a discharge pipe can terminate safely, and look at the route pipework takes to each bathroom. They will also ask how many people live in the house and how often showers and baths run at the same time, because that decides the cylinder size. Loft tanks that come out free up space and remove a source of freezing risk in winter, which some households count as a benefit in its own right. If any of those checks come back weak — a narrow old supply pipe, poor flow at peak times or no sensible discharge route — the honest advice may be to improve the supply first, or to look at a different hot water arrangement altogether. A good installer will tell you that before quoting for a cylinder.

Start with a flow test, not a brochure. If the mains can deliver, a conversion can transform a house's showers; if it can't, the money is better spent elsewhere.

Questions people ask

Can I use an unvented cylinder in a vented system?

Not as a straight swap. Converting means feeding the new cylinder from the mains, fitting its safety equipment and discharge route, and usually removing the loft tanks.

Would a combi be simpler than an unvented cylinder?

Sometimes. Combis heat water on demand and need no cylinder, but they struggle when several outlets run together. Our guide on replacing a cylinder versus converting to a combi compares the two.

Will my existing boiler work with an unvented cylinder?

Often, if it is a system or regular boiler in good condition. The controls and pipework may need changing, which is checked during the survey.

Does an unvented cylinder need servicing?

Its safety valves and expansion vessel should be checked regularly — annually is the usual recommendation.

Thinking about a conversion?

Call 07891 410 960. We give a written quote before any work begins.

Keep reading

Related service
Central heating services
Visit central heating hub
WhatsApp
Call nowFree quote