Air Conditioning Blowing Warm Air

The indoor unit runs and the fan blows, but the air isn't cold..

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes

The indoor unit runs and the fan blows, but the air isn't cold.

What is actually going on

The indoor unit runs and the fan blows, but the air isn't cold.

The realistic causes, in order

Low refrigerant charge caused by a leak, which is the most common single cause A dirty filter or blocked indoor coil restricting airflow across the heat exchanger An outdoor unit that can't reject heat because the coil is blocked or the fan has failed

What we test on site

Refrigerant pressures and superheat against the manufacturer's data A leak test where pressures indicate loss, because topping up without finding the leak is not lawful practice Indoor and outdoor coil condition and airflow

Questions we get asked

Why is air conditioning blowing warm happening on an air conditioning system?

Low refrigerant charge caused by a leak, which is the most common single cause

What normally puts air conditioning blowing warm right?

Where a leak is found it is repaired and the system recharged correctly, rather than simply topped up.

Is it safe to keep using the system with air conditioning blowing warm?

Refrigerant work is controlled under F-Gas regulations and must be carried out by a certified engineer. We are REFCOM registered for this work.