Get in touch 07891 410 960
Fault finder

Unvented Cylinder Discharging Water

Water running from the tundish under the cylinder, either continuously or after each heating cycle..

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes

Water running from the tundish under the cylinder, either continuously or after each heating cycle.

What is actually going on

Water running from the tundish under the cylinder, either continuously or after each heating cycle.

The realistic causes, in order

An expansion vessel or internal air bubble that has lost its cushion, so expansion has nowhere to go A passing expansion relief valve held open by debris A failed temperature and pressure relief valve, which is the safety device of last resort

What we test on site

Which valve is actually discharging, identified at the tundish Incoming mains pressure and the pressure reducing valve setting Vessel charge, or air-gap re-charge on a bubble-top cylinder

Get an unvented cylinder discharging diagnosed properly

Re-charging the vessel and replacing the passing valve resolves the majority of cases.

Questions we get asked

Does an unvented cylinder discharging mean the cylinder needs replacing?

An expansion vessel or internal air bubble that has lost its cushion, so expansion has nowhere to go

What normally puts an unvented cylinder discharging right?

Re-charging the vessel and replacing the passing valve resolves the majority of cases.

Is it safe to keep using the system with an unvented cylinder discharging?

A discharging temperature and pressure relief valve is a safety warning, not a nuisance. It should be investigated promptly by someone qualified in unvented hot water systems.

Where to go next

WhatsApp
Call nowFree quote