If your home has a system or regular boiler, hot water is stored in a cylinder until you need it. The size of that cylinder decides how many showers and baths you can run before the water goes cold and has to reheat.
This guide explains the factors that set the right size, gives rough starting points, and covers the space and installation questions that come with changing cylinder size. Final sizing should always come from a survey of your home and habits.
What affects the right size
- How many people live in the home, now and in the next few years.
- How many bathrooms, and how many showers may run at the same time.
- Whether you use baths often, which take far more water than showers.
- Shower type: high-flow mixer showers use more hot water than low-flow heads.
- How quickly the boiler can reheat the cylinder, known as recovery time.
- The space available in the airing cupboard or loft.
Rough starting points
These are typical industry rules of thumb, not a design. Always confirm with an installer.
| Household | Bathrooms | Typical starting capacity |
|---|---|---|
| 1–2 people | 1 | Around 120–150 litres |
| 3–4 people | 1–2 | Around 150–210 litres |
| 4–5 people | 2 | Around 210–250 litres |
| 5+ people | 2–3 | Around 250–300 litres or more |
A common rule of thumb is roughly 35–45 litres per person, adjusted for baths, shower types and recovery time.
Too small or too large
An undersized cylinder is easy to spot: the second shower runs lukewarm, or someone has to wait for a reheat before running a bath. It is the most common complaint in growing households.
An oversized cylinder is less obvious but still costs you. A larger body of water takes longer to heat, loses more heat while standing, and takes up more space. If most of it is never used, you are paying to keep water hot for nothing.
Recovery time matters as much as capacity. A cylinder that reheats quickly from a well-sized boiler can be smaller than one with a slow coil, because it refills with hot water faster between uses.
Cylinder types and sizing
Unvented
Runs at mains pressure, giving strong showers. Sizing must also consider the incoming mains flow.
- G3 qualified installer required
- Needs expansion and discharge arrangements
Vented
Fed from a cold tank in the loft. Pressure depends on the height of the tank.
- Simpler controls
- Needs loft tank space
Smart or stratified
Some cylinders heat only part of the tank when demand is low, which can change how capacity is judged.
- Ask how usable volume is measured
Space around the cylinder
Unvented cylinders need room for an expansion vessel, safety valves and a discharge pipe route, as well as the cylinder itself. A survey measures the space so the chosen size actually fits with everything it needs around it.
Coil size, boiler output and reheat
An indirect cylinder is heated by water from the boiler passing through a coil inside it. A larger, high-performance coil and a boiler with enough output can reheat the cylinder much faster than an older, smaller coil. That is why two cylinders of the same size can feel very different in daily use.
Many systems also have an immersion heater as a backup. It is useful if the boiler is off, but heating a whole cylinder by immersion is usually slower and can cost more. Scheduling the boiler to reheat before busy times, such as early morning, often gives the best results.
Planning for change
If a new bathroom or ensuite is likely, or children will soon be teenagers taking longer showers, size for that future. Replacing a cylinder again a few years later is far more disruptive than choosing a slightly larger one now. Equally, if the household is shrinking, a smaller cylinder may save space and energy.
Size a cylinder for the household you have and the one you expect, not just for the cupboard that happens to be there. A short survey gets the balance right.