When an air conditioner cools a room, warm, humid air passes over a cold coil in the indoor unit. Moisture condenses on the coil, just like water on a cold glass, and drips into a tray. That water, called condensate, has to be drained away continuously.
This guide explains how condensate is handled on a home split system, the difference between gravity drainage and pumps, and what to discuss at survey so the result is reliable and tidy.
How much water are we talking about?
It varies with humidity, room size and how hard the unit is working. On a warm, muggy day a unit can produce a noticeable amount over the course of the day. In dry weather it may produce very little. Either way, the drain needs to handle the peak, not the average.
In heating mode the indoor unit does not produce condensate, but the outdoor unit can, as it defrosts in cold weather. That water normally drains from the base of the outdoor unit and needs a sensible place to go.
Gravity or pump
Gravity drainage
The simplest option: the pipe falls continuously from the indoor unit to a drain point or outside.
- No moving parts
- Needs a steady fall
- Preferred where possible
Condensate pump
A small pump lifts water where gravity cannot work, such as an indoor unit on an internal wall.
- Allows more unit positions
- Makes a little noise
- Needs a power supply
Where the condensate can go
- Outside to a gully or drain, often the neatest route for units on external walls.
- Into an internal waste pipe with a suitable trap or connection to stop smells.
- To a soakaway or garden area where permitted and practical.
- Not left dripping onto a path, patio or neighbour's property.
Planning checks at survey
| Check | Why |
|---|---|
| Indoor unit position | Determines whether gravity drainage is possible |
| Route to a drain | Shorter, simpler routes are more reliable |
| Fall along the run | Water must not sit in the pipe |
| Frost risk outside | External pipes can freeze in winter |
| Appearance | Pipes can be run in trunking or hidden |
Why drainage problems happen
Water dripping from an indoor unit is usually a drainage issue rather than a fault in the cooling itself. A pipe without enough fall, a kink, or a pump that cannot cope can all cause it. That is why the drain route deserves as much attention as the refrigerant pipes when a system is planned.
Getting it right at installation avoids marks on walls and floors later. If a pump is used, ask where it will sit and how it is powered.
Pumps: where they go
When a condensate pump is needed, it is often fitted inside the indoor unit's trunking or in a nearby void. It needs a power supply and should be reachable if it ever needs attention. A well chosen, well positioned pump is quiet enough that most people stop noticing it, but it is still worth hearing how it will be arranged before installation day.
Hiding the pipe
Condensate pipes are usually small, but on show they can look untidy. Common options are to run them inside the wall, alongside the refrigerant pipes in neat trunking, or straight through the wall behind the indoor unit to the outside. Each has trade-offs between appearance, access and the fall needed for gravity drainage.
Pipes hidden in walls or ceilings need to be installed carefully, with joints that will not leak and a fall that will not reverse if the building moves slightly. Where possible, keep at least some access to the route.
Outdoor unit water
In heating mode, the outdoor unit periodically defrosts and releases water from its base. Positioning the unit so this water drains away safely, rather than onto a path where it could freeze, is part of good planning. Ground-mounted units on a base and wall-mounted units on brackets each need a sensible place for this water to go.
Talking it through at survey
Ask the installer to point to where the condensate pipe will run and where it will end. It is a simple question, but the answer tells you a lot about how thoroughly the job has been planned.
Questions people ask
Does air conditioning need a drain?
Yes. Split systems produce condensate in cooling mode, which must drain away through a pipe to a suitable point.
Can condensate go into my sink waste?
Often it can connect to an internal waste pipe with the right fitting and trap, depending on the route.
Are condensate pumps noisy?
They make a low noise when running. Positioning and the model chosen can reduce how noticeable it is.
Why is water dripping from my indoor unit?
It is often a drainage issue such as a blocked or poorly sloped pipe. Our dripping water guide covers the usual causes.
Cooling is the headline, but drainage is what keeps the installation tidy for years. A good route on the quote is a sign of a well planned job.