Sizing guide

What size air conditioner do I need?

Floor area is where sizing starts, not where it ends. The room's glass, roof and aspect usually matter just as much.

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes

Online BTU calculators ask for a room's length and width and give you a number. That number is a reasonable first guess for an ordinary room with an ordinary window. It can be well out for a loft bedroom under a hot roof, a conservatory, or a kitchen with a wall of glass facing south.

This guide explains what goes into sizing so you can make sense of the figures you see, and why a survey is the point where the guess becomes a decision.

kW and BTU: the same thing in different units

Air conditioner capacity is quoted either in kilowatts (kW) or British Thermal Units per hour (BTU/h). They measure the same thing: how much heat the unit can move. One kilowatt is roughly 3,412 BTU/h, so a 2.5 kW unit is around 8,500 BTU/h and a 3.5 kW unit around 12,000 BTU/h.

Manufacturers usually quote separate cooling and heating capacities, and the heating figure is often a little higher. If you want the unit to heat the room in winter as well as cool it in summer, both figures matter.

What pushes the size up or down

Room size and ceiling height

The volume of air and the surfaces it touches.

  • Larger floor area needs more capacity
  • High or vaulted ceilings add volume
  • Open-plan spaces count as one room

Glazing and orientation

Sunlight through glass is often the largest heat gain.

  • South and west facing rooms gain most
  • Large windows, bifolds and roof lights add load
  • Blinds and shading help

Insulation and construction

How quickly the room gains and loses heat.

  • Well-insulated rooms need less
  • Rooms under a roof run hotter in summer
  • Older solid walls behave differently from new builds

How the room is used

People and equipment produce heat too.

  • Home offices with computers
  • Kitchens with cooking appliances
  • Bedrooms used mainly at night

Loft rooms and conservatories run hotter

Rooms directly under a roof pick up heat from the roof covering all day, then hold it into the evening. Loft conversions and top-floor rooms often need more capacity than their floor area suggests.

Conservatories are the extreme case. Glass gains heat quickly in sun and loses it quickly on cold nights, so the unit has to cope with both ends. Sizing them on floor area alone almost always leads to a unit that struggles.

Why too big or too small both cause problems

An undersized unit runs flat out and still fails to reach the set temperature on the hottest or coldest days. An oversized one cools the room quickly and then cycles on and off, which can leave the air feeling clammy because it has not run long enough to remove moisture. Modern inverter units cope with a range of loads better than older ones, but matching capacity to the room still gives the best comfort.

Where several rooms are served by one outdoor unit, the indoor units are each sized for their room and the outdoor unit for the combination, which is another reason to look at the house as a whole.

A sizing figure is only as good as the information behind it. Tell us about the room, and the visit will take care of the rest.

Questions people ask

How do I convert kW to BTU?

Multiply kilowatts by roughly 3,412. For example, 2.5 kW is about 8,500 BTU/h and 3.5 kW is about 12,000 BTU/h.

Is an online BTU calculator accurate?

It gives a starting point for an ordinary room. Rooms with lots of glass, a roof above or a south-facing aspect often need a different size, which is why a survey matters.

Should I just buy a bigger unit to be safe?

Not necessarily. An oversized unit can cycle on and off and leave the room feeling damp. Matching the unit to the room gives steadier comfort.

Get your rooms sized properly

Free in-home design and quote, with a fixed price in writing for the system that suits each room.

Air conditioning indoor unit mounted high on a bedroom wall

Who does the work

  • Gas Safe registered engineers — registration 554328
  • REFCOM registered for F-Gas refrigerant work
  • Worcester Bosch accredited installer
  • John The Plumb Ltd, company registration 10026483

Keep reading

Related service
Air conditioning quote
Visit air conditioning hub
WhatsApp
Call nowFree quote