Signs the system water is dirty
- Radiators cold at the bottom while warm at the top.
- Black water when a radiator is bled.
- Banging, kettling or gurgling noises from the boiler.
- Radiators slow to warm or heating uneven across the house.
- Frequent pump or valve problems.
What the standard asks for
BS 7593 is the British Standard for treating water in domestic heating systems. In short, it expects a system to be cleaned before a new boiler is connected, filled with an inhibitor to slow corrosion, and protected with a suitable filter. It also recommends checking the inhibitor level regularly afterwards.
Boiler manufacturers refer to these steps in their installation instructions and guarantee terms, and the engineer records the cleaning method and the inhibitor used on the Benchmark commissioning checklist.
Water treatment on a new boiler installation
- 1
Assess the system
The engineer looks at the age of the system, the radiators and the condition of the water.
- 2
Clean
Depending on the system, this may be a chemical clean, a mains-pressure flush or a power flush to shift sludge and debris.
- 3
Fit a filter
A magnetic filter on the return pipe catches iron oxide and debris that keeps circulating.
- 4
Add inhibitor
Inhibitor is dosed to the system volume to protect metals against corrosion.
- 5
Record and label
Details go on the Benchmark record, and many installers leave a label showing the treatment date.
The three parts of protection
Cleaning
Removes what is already in the system. Without it, a new boiler inherits old sludge on day one.
- Chemical clean
- Mains flush
- Power flush where needed
Inhibitor
A chemical treatment that slows corrosion and scale. It is gradually used up and diluted, so it needs topping up.
- Dosed to system volume
- Checked at servicing
Filter
Catches particles that still form over time and makes them easy to remove at service.
- Fitted on the return
- Cleaned during servicing
Keeping it right afterwards
Inhibitor does not last forever. Small leaks, repressurising or draining down a radiator all dilute it. During an annual service the engineer can test the water and clean the filter, and top up the inhibitor if the level is low.
If you have to top up the boiler pressure often, that is a sign water is being lost and fresh, untreated water is going in. Have the cause found, because constant topping up gradually undoes the treatment.
Old systems and new boilers
Older systems with original steel radiators, microbore pipework or a long history of sludge need extra care. Microbore pipes block more easily, and heavily corroded radiators can release debris during cleaning. The installer may recommend replacing the worst radiators, rather than trying to flush them, so the new boiler starts on a sound system.
Open-vented systems with a feed and expansion tank in the loft can also draw air in if the tank or pump position is wrong, which speeds up corrosion. Converting to a sealed system, or correcting the setup, may be part of the advice when a new boiler is fitted.
Hard water and scale
In hard water areas, scale can form in the hot water side of a combi and in the heat exchanger. Some manufacturers recommend scale protection on the incoming cold supply. Ask whether it is needed for your area and model.
Clean water is the cheapest protection a heating system can have. Get it right when the boiler goes in and the rest of the system will thank you for years.