Get in touch 07891 410 960
Heating systems

Draining a central heating system: when it is needed and how it is done

Draining down is part of many heating jobs, from replacing a radiator to fitting a new boiler. Refilling properly afterwards matters just as much.

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes

Your central heating holds water that circulates between the boiler and the radiators. Draining the system means emptying that water so work can be done on the pipework, the boiler or the radiators. It is a routine step for heating engineers, but it is also a job where mistakes cause leaks, airlocks, corrosion and boilers that will not restart.

This guide explains why systems are drained, how the two main kinds of system differ, and what a good refill looks like. It is not a step-by-step DIY guide. On a sealed system in particular, draining and refilling involves pressure settings, the boiler and treatment chemicals, and should be done by a heating engineer; anything involving the boiler itself needs a Gas Safe registered engineer.

Common reasons to drain a system

  • Replacing a boiler, where the old appliance has to come off and the system is usually cleaned.
  • Replacing or adding radiators, or moving pipework.
  • Cleaning a system full of sludge, such as during a power flush or chemical clean.
  • Repairing a leak on pipework that cannot be isolated.
  • Changing the system type, such as converting from open-vented to sealed.

Sealed and open-vented systems drain differently

Sealed system

Common with combi and system boilers. Runs under pressure, set using a filling loop.

  • Pressure must be released safely
  • Refilled to the manufacturer's pressure
  • Expansion vessel charge matters

Open-vented system

Fed by a small feed-and-expansion tank in the loft.

  • Tank refills the system automatically
  • Feed must be isolated before draining
  • Air removal is mostly by venting radiators

How a professional drain-down usually works

The engineer switches off the boiler and lets the system cool, isolates the water feed, and connects a hose to a drain-off valve at a low point so the water can run to a suitable drain. Radiator bleed valves are opened, usually starting upstairs, to let air in so the water can flow out. On a sealed system, the pressure falls to zero as it empties. On an open-vented system, the feed tank in the loft is isolated first so it does not keep topping the system up.

Not every radiator drains completely through a single valve, and some systems have low sections or microbore pipework that hold water. Experienced engineers know where to expect this and plan the work around it.

Refilling is where problems start

Refilling slowly and venting each radiator lets air out before it causes airlocks. Fresh water has to be treated with inhibitor, because new water brings fresh oxygen, which drives corrosion in steel radiators. On a sealed system, the pressure is set to the manufacturer's cold fill figure and the boiler is then run and the system re-vented, with the pressure checked again once air has been released.

A system that is drained and refilled without inhibitor, or partly drained repeatedly, often develops sludge and cold radiators within a few years. That is why boiler installations should include cleaning and treating the system, and why a recorded inhibitor dose is part of good practice.

Symptoms after a poor refill

SymptomUsual cause
Radiators cold at the topAir still trapped
Boiler pressure falls over the next daysAir working out of the system, or a disturbed joint weeping
Gurgling and noise from pipesAir in the system
Boiler will not fireLow pressure or an airlock at the boiler
Sludge returning quicklyNo inhibitor added

Draining as part of a new boiler installation

When a new boiler is fitted, the system is normally drained so the old appliance can be removed and the new one connected. This is also the natural point to clean the system, because the water is being changed anyway. Depending on the condition of the radiators and pipework, that may be a chemical clean or a power flush, followed by inhibitor and a magnetic filter to protect the new boiler's heat exchanger.

It is worth asking your installer how they will clean and treat the system, and whether the inhibitor dose will be recorded. A boiler installed onto dirty, untreated water starts life at a disadvantage, and manufacturer guarantee terms commonly expect the system to have been cleaned to a recognised standard.

Questions people ask

How long does it take to drain a central heating system?

It depends on the size of the system and the pipework. Refilling, venting and treating the water properly also takes time.

Do I need to drain the system to replace a radiator?

Not always. Radiators with working isolation valves can sometimes be removed without a full drain-down.

Why does fresh water need inhibitor?

New water contains oxygen that causes corrosion in steel radiators and pipes. Inhibitor slows this and helps protect the boiler.

Can I drain a combi system myself?

A sealed system involves pressure settings and the boiler, so it is safer to use a heating engineer. Boiler work needs a Gas Safe registered engineer.

Is draining the same as a power flush?

No. A power flush circulates water and cleaning chemicals at high flow to shift sludge before the system is refilled and treated.

Who does the work

  • Gas Safe registered engineers — registration 554328
  • Worcester Bosch accredited installer
  • John The Plumb Ltd, company registration 10026483

Draining is easy to start and easy to get wrong at the end. Judge any work on your heating by how the system was refilled, vented and treated, not just by how quickly it was emptied.

Planning work on your heating system?

We install boilers, radiators and complete heating systems, and include cleaning and treatment where needed. Book a free in-home survey.

Keep reading

Related service
Central heating
Visit central heating hub
WhatsApp
Call nowFree quote