When you compare air conditioners, the brochure will quote SEER and SCOP figures and an energy band such as A++ or A+++. They look similar to the A-rating on a fridge, but each figure measures a different job, and the one that matters most depends on how you plan to use the system.
This guide explains what each rating means, how they are measured, what the bands are and how to use them sensibly alongside the other things that decide running costs.

The two key ratings
SEER: cooling
Seasonal Energy Efficiency Ratio. The cooling delivered over a typical cooling season divided by the electricity used. A SEER of 7 means roughly seven units of cooling for each unit of electricity.
- Higher is better
- Most relevant if you mainly cool
SCOP: heating
Seasonal Coefficient of Performance. The heat delivered over a typical heating season divided by the electricity used. A SCOP of 4 means roughly four units of heat for every unit of electricity.
- Higher is better
- Key if you use it as an air-to-air heat pump
Why the word seasonal matters
Older ratings, called EER and COP, measured efficiency at one fixed test condition. Real weather is not fixed. Seasonal ratings test the unit across a range of outdoor temperatures and part-load conditions, then weight the results for a typical season. That reflects how inverter units actually spend their time: mostly at part load, not flat out.
SCOP figures are calculated for different climate zones. The label usually shows the average climate figure, which is broadly representative for much of the UK. Some manufacturers also publish warmer and colder climate figures in their technical data.
How the label bands work
Bands run from A+++ down to D for cooling and heating on most room air conditioners.
| Label shows | What it tells you |
|---|---|
| Cooling band and SEER | Seasonal cooling efficiency |
| Heating band and SCOP | Seasonal heating efficiency for the stated climate |
| Design load (kW) | The capacity the ratings were calculated at |
| Annual energy figure (kWh) | Estimated use under the standard test season, not your home |
| Sound power (dB) | Indoor and outdoor noise levels, worth comparing too |
Using the ratings sensibly
- Compare like with like: the same capacity and the same type of unit.
- If you plan to heat with the system, give more weight to SCOP than SEER.
- Treat the annual kWh figure as a comparison tool, not a forecast of your bill.
- Remember installation quality matters: correct sizing, a good outdoor position and a tight, clean refrigerant circuit all affect real-world performance.
- Weigh noise ratings and controls alongside efficiency, especially for bedrooms.
What the ratings cannot tell you
Energy labels are measured in standard conditions on a laboratory rig. In your home, a unit fitted in a sunny conservatory, cramped against a wall outside or sized poorly for the room will perform differently from its label. The rating is a fair way to compare models; the survey and installation decide how close you get to it.
Running costs also depend on your electricity tariff, how long you run the system and the temperatures you set. Small changes in set point often make more difference than small differences in SEER.
A worked example of reading the label
Imagine two 2.5kW wall units for a bedroom. One shows a SEER of 8.5 and a SCOP of 4.6; the other a SEER of 7.0 and a SCOP of 4.0. If you mainly want cooling on a few hot summer nights, the difference in SEER will make only a modest difference to your yearly bill, because the hours of use are low. If you plan to use the unit to heat the room for much of the year, the higher SCOP becomes more valuable, because heating hours in the UK are far longer than cooling hours.
After efficiency, compare the indoor noise level at the lowest fan speed, the controls and app features, and how the unit looks on the wall. Those details often decide which unit you are happiest living with. Your installer can confirm which models suit the room and outdoor position.
Why outdoor position affects real efficiency
An outdoor unit squeezed into a tight corner, boxed in by a decorative cover or placed where it recirculates its own exhaust air has to work harder than the test rig assumed. In heating mode, a unit sitting where snow and leaves collect, or where it cannot drain defrost water, also loses performance. A good position with free airflow on all sides is one of the cheapest ways to get close to the label figures.
Comparing air conditioning options?
We can talk you through the ratings of the units that suit your rooms and give you a fixed written price. Ask for a free in-home survey.
Use SEER and SCOP to narrow the shortlist, then let the survey decide the capacity and position. A slightly lower rated unit fitted well beats a top-rated one fitted badly.