Walk through any boiler brochure and you will see the same thing: A-rated, 92 per cent or more efficient, sometimes A+ with the right controls. It is reassuring, but it can also be confusing when every model on the page seems to score the same.
This guide explains where those numbers come from, the difference between the old SEDBUK bands and today's ErP labels, why a controls package can lift the rating, and the practical things that decide how efficient a boiler really is once it is on your wall.
Where the ErP label comes from
Since September 2015, boilers sold in the UK have carried an energy label under the European ErP (Energy-related Products) rules, which the UK kept after leaving the EU. The label gives a seasonal space heating efficiency figure and a letter band. For combination boilers it also gives a separate water heating rating.
Seasonal efficiency is a calculated average across a typical heating season rather than a single best-case test. It takes account of the boiler running at part load, which is how most boilers spend most of their time. For a modern gas condensing boiler the space heating figure usually sits in the low 90s, which places it in band A.
In England, the Boiler Plus standard also sets a minimum ErP seasonal efficiency of 92 per cent for gas boilers fitted in existing homes, so in practice every new gas boiler installed meets that bar.
The ratings you may see
| Rating | What it refers to |
|---|---|
| ErP space heating band (A+++ to G) | Seasonal efficiency of the boiler for heating, shown on the product label |
| ErP water heating band | How efficiently a combi heats domestic hot water, measured against a usage profile |
| Package label (often A+) | The boiler combined with a qualifying temperature control, which adds a few percentage points |
| SEDBUK band (A to G) | The older UK scale, still seen on some existing boilers and older paperwork |
| Percentage efficiency | The seasonal figure behind the band, usually quoted to one decimal place |
Bands and figures are taken from the manufacturer's published product data. They describe test conditions, not your house.
Why a thermostat can turn an A into an A+
The ErP system recognises that controls change how efficiently a boiler runs. Each temperature control is assigned a class from I to VIII, worth a set uplift of up to five percentage points. A boiler paired with a weather compensation sensor and a modulating room thermostat, for example, can earn a combined package label higher than the boiler on its own.
That uplift reflects something real. Controls that let the boiler run at a lower, steadier output keep it condensing for longer and avoid wasteful on-off cycling. It is one reason a well-chosen control is worth more than chasing a fraction of a percent between two boilers.
What decides real-world efficiency in your home
- The flow and return temperatures the system runs at: cooler return water means more condensing.
- Correct sizing: a boiler far bigger than the house needs cycles on and off more often.
- Modulation range: a boiler that can turn down low copes better with mild days.
- Clean system water: sludge and scale insulate heat exchangers and cut output.
- Controls set up properly, not just fitted and left on default settings.
- An annual service by a Gas Safe registered engineer to keep combustion and condensate drainage right.
Reading the brochure with a sceptical eye
- Two boilers are 93.8 and 94.1 per cent. Does it matter?
- Very little. The difference is small compared with the effect of sizing, flow temperature and controls. Pick on reliability, warranty terms, fit for your system and after-sales support.
- Does a higher kW boiler mean higher efficiency?
- No. Output and efficiency are separate. A larger output only helps if you need it, mainly for combi hot water flow rates.
- Is there a point paying more for an A+ package?
- If the extra control suits how you live and your system can take advantage of lower flow temperatures, often yes. Ask what the control will do day to day, not just what label it earns.
Efficiency and running costs in plain terms
Efficiency describes how much of the gas you buy becomes heat in your home. If a boiler converts 90 per cent of its fuel into useful heat, the other 10 per cent is lost, mostly through the flue. An old non-condensing boiler might have managed considerably less, which is why replacing a very old boiler often makes a noticeable difference.
But efficiency does not decide how much heat your home needs. A draughty house with a perfectly efficient boiler still uses a lot of gas. Insulation, draught-proofing and sensible heating schedules reduce the demand itself, while a well set-up boiler makes sure what you do use is turned into heat with as little waste as possible. The best results usually come from tackling both sides together.
Questions people ask
What does an A-rated boiler mean?
It means the boiler's seasonal space heating efficiency, as calculated under the ErP rules, falls into band A. For a gas condensing boiler that typically means around 90 per cent or more.
Are all new boilers A-rated?
Almost all new gas boilers sold in the UK are band A for space heating. In England, Boiler Plus requires at least 92 per cent ErP seasonal efficiency for gas boilers installed in existing homes.
How can I find my current boiler's efficiency?
Look up the make and model in the manufacturer's literature or a product database. Older boilers often carry a SEDBUK band instead of an ErP label.
Will a new A-rated boiler halve my gas bill?
Not necessarily. Savings depend on how inefficient the old boiler was, how the new system is set up and how you use your heating. Be wary of any fixed savings promise.
Does the hot water rating matter for a combi?
Yes, if you use a lot of hot water. The water heating band tells you how efficiently the combi heats tap water, which is a separate question from heating the house.
Treat the letter on the label as the entry ticket, not the decision. The boilers that save money are the ones sized properly, set up to run cool and paired with controls you will actually use.