Get in touch 07891 410 960
Underfloor heating

Underfloor heating in an existing floor: screed, overlay and suspended timber

New builds get underfloor heating with the screed. Existing homes need a system that fits the floor they already have.

Gas Safe registered (554328) Worcester Bosch accredited Free, no-obligation quotes

Underfloor heating is easy to plan in a new extension where the floor is being built from scratch. In an existing room, the question becomes how much floor height you can spare and what is already underneath.

There are several ways to add wet underfloor heating to an existing home. This guide explains the main ones, the trade-offs in height and warm-up time, and what a survey looks at before recommending a method.

The main methods compared

MethodBest forHeightResponse
Traditional screedFloors being dug up or rebuiltMost build-upSlow but very even
Low-profile overlaySolid floors that cannot be loweredLow build-upFaster
Between joistsSuspended timber floors with access from above or belowLittle or noneModerate
On top of joistsTimber floors being re-boardedSome build-upModerate to fast

Heights depend on the system, insulation and finish, so the survey measures your floor rather than relying on brochure figures.

Height: the first question

Any system that sits on top of the existing floor raises it. That affects door thresholds, kitchen units, skirting and the step into adjoining rooms. Low-profile overlay systems are designed to keep this increase small, but even a modest rise needs planning around doors and appliances.

If the floor is being taken up anyway, for example during a kitchen renovation, digging out and laying insulation and screed can give the best long-term result. In timber-floored rooms, laying pipes between the joists can avoid any height change at all.

Insulation makes or breaks it

  • Heat should go up into the room, not down into the ground or the room below.
  • Overlay systems usually include an insulation board under the pipes.
  • Between-joist systems need insulation below the pipes and spreader plates above.
  • Poorly insulated floors warm up slowly and cost more to run.

Floor finishes

Tile and stone

Conduct heat very well and are a natural match for underfloor heating.

  • Fast heat transfer

Engineered wood and laminate

Work with underfloor heating when the manufacturer approves it and the floor temperature is limited.

  • Check the finish's limits

Carpet

Possible with a low tog underlay, but thick carpet and underlay slow heat transfer.

  • Choose low tog products

What a retrofit involves

  1. 1

    Survey

    Check the floor construction, available height, heat loss, boiler and where the manifold can go.

  2. 2

    Prepare

    Clear the room, level the floor where needed and lay insulation.

  3. 3

    Lay the pipes

    Loops are laid in the chosen system and pressure-tested.

  4. 4

    Finish the floor

    Screed, boards or the overlay surface go down, followed by the final finish.

  5. 5

    Connect and commission

    The manifold is connected to the heating system, balanced and set up with thermostats.

Rooms that suit a retrofit best

Kitchens, dining areas and hallways with hard floors are often the easiest wins, because tile and stone transfer heat well and these rooms are frequently refloored anyway. Ground floor rooms with solid floors can take overlay systems, while upstairs bedrooms with timber floors suit joist-based methods. Rooms with deep carpet, very limited height at doors or complex fitted furniture take more thought. The survey looks at each room on its own merits, and it is common to fit underfloor heating in one or two rooms while keeping radiators elsewhere.

Running costs and boiler compatibility

Wet underfloor heating runs from the boiler, so the running cost depends on the heat the rooms need and how efficiently the boiler works. Because floors run at lower water temperatures than radiators, condensing boilers can operate in their more efficient range for more of the time, especially in systems that are largely underfloor heating.

In a retrofit, the boiler capacity, manifold position and controls all need checking. Adding a large heated floor to a system that is already stretched may need a boiler review. The survey looks at this before recommending a method, so the new floor does not leave other rooms short of heat.

Disruption to expect

A screed retrofit means the room is out of use while the floor is prepared and the screed cures. Overlay systems are quicker and often let the room be back in use sooner. Timber floor methods depend on access from above or below. Ask for a clear outline of the stages so you can plan around them.

Most existing floors can take underfloor heating in one form or another. The right method is the one that respects your floor height, your finish and the rest of the project.

Questions people ask

Can underfloor heating go on top of an existing floor?

Yes. Low-profile overlay systems are designed to sit on top of existing solid floors with a small height increase.

Can I have underfloor heating upstairs?

Often, yes. Timber floors can take between-joist or over-joist systems, with insulation to direct heat upwards.

Is a retrofit slower to heat up?

Overlay systems usually warm faster than thick screed. Screed is slower but holds heat well.

Do I need to remove my radiators?

Not necessarily. Many homes keep radiators in some rooms and add underfloor heating in others.

Thinking about underfloor heating?

We install wet underfloor heating for extensions, new floors and retrofits. Free in-home survey, fixed-price written quote.

Low-profile underfloor heating panels laid over an existing kitchen floor

Who does the work

  • Gas Safe registered engineers — registration 554328
  • Worcester Bosch accredited installer
  • John The Plumb Ltd, company registration 10026483

Keep reading

Related service
Underfloor heating installation
Visit central heating hub
WhatsApp
Call nowFree quote